B2F Double-Flange Limiting Expansion Joint

Keywords:

B2F Double-Flange Limiting Expansion Joint

Product Inquiries:

Product Description

Technical Specifications for B2F Type (VSSJA-2) Double-Flange Limiting Expansion Joints

Product Introduction

The B2F type (VSSJA-2) double-flange limit expansion joint is developed on the basis of the VSSJA flange expansion joint.

The B2F type (VSSJA-2) double-flange limit expansion joint operates by connecting to equipment such as valves or flanges on both sides of the joint. Its working principle involves adding a short limiting flange pipe and using extended bolts to securely connect the joint to the limiting device. At the maximum expansion/contraction point, the dimensions are locked with nuts, allowing the pipeline to expand and contract freely within the permissible range. While protecting the pipeline and associated equipment, this design also facilitates future installation, removal, and maintenance. It is suitable for applications involving thermal expansion and contraction of pipelines, uneven foundation settlement, pipelines with a certain degree of slope, bends, or those subjected to significant vibration.

Users can select the expansion joint product that best suits their specific application needs.

Suitable for connecting pipelines conveying water, oil, gas, slurries, and particulate media.

This product complies with the technical requirements of GB/T12465-2017.

Structure and Material

  Name Quantity Material
1 Body 1 Carbon steel (Q235A)
or ductile iron (QT400–15)
2 Sealing rubber Sealingmg 1 Natural Rubber (NR)
Nitrile rubber (NBR) or chloroprene rubber (CR)
3 Pressing Cap Follower 1 Carbon steel (Q235A)
or ductile iron (QT400–15)
4 Limited Short Pipe 1 Carbon steel (Q235A)
5 Nut 4n Carbon steel (Q235A galvanized)
6 Long stud n Carbon steel (Q235A galvanized)
7 Bolt n Carbon steel (Q235A galvanized)

Note: For VSSJA-2 double-flange limit expansion joints with a nominal diameter greater than DN300, it is recommended to use steel structural components as a whole. If there are specific material requirements (e.g., stainless steel, etc.), please specify in advance.

Technical Parameters of B2F Type (VSSJA-2) Double-Flange Limiting Expansion Joints (PN 0.6, 1.0 MPa)

Nominal Diameter
Nominal
Dia.DN
Pipe outer diameter
Pipe O.D.
Dw
External dimensions
Overall
Dimension
Expansion amount
Linear
Movement
△L
Flange Connection Dimensions
Flange Connection Dimension
0.6MPa 1.0MPa
L L1 D D1 n-do D D1 n-dO
65  76  340  105  50  160  130  4-φ14 185  145  4-φ18
80  89  190  150  4-φ18 200  160  8–φ18
100  108  210  170  220  180 
114 
125  133  240  200  8–φ18 250  210 
140 
150  159  265  225  285  240  8-φ22
168 
200  219  320  285  340  295 
250  273  370  335  12-φ18 395  350  12-φ22
300  325  350  130  65  440  395  12-φ22 445  400 
350  377  490  445  505  460  16-φ22
400  426  540  495  16-φ22 565  515  16–φ26
450  480  595  550  615  565  20–φ26
500  530  645  600  20–φ22 670  620 
600  630  755  705  20–φ26 780  725  20–φ30
700  720  860  810  24-φ26 895  840  24–φ30
800  820  590  220  130  975  920  24–φ30 1015  950  24-φ33
900  920  1075  1020  1115  1050  28–φ33
1000  1020  1175  1120  28–φ30 1230  1160  28–φ36
1200  1220  1405  1340  32–φ33 1455  1380  32–φ40
1400  1420  1630  1560  36–φ36 1670  1590  36–φ42
1500  1520  1730  1660  - - -
1600  1620  1830  1760  40–φ36 1915  1820  40–φ48
1800  1820  2045  1970  44–φ40 2115  2020  44–φ48
2000  2020  2265  2180  48–φ42 2325  2230  48–φ48
2200  2220  2475  2390  52–φ42 2550  2440  52–φ56
2400  2420  2685  2600  56–φ42 2760  2650  56–φ56
2600  2620  600  240  150  2905  2810  60–φ48 2960  2850  60–φ56
2800  2820  3115  3020  64–φ48 3180  3070  64–φ56
3000  3020  3315  3220  68–φ48 3405  3290  68–φ60
3200  3220  3525  3430  72–φ48 3635  3510  72–φ60
3400  3420  3735  3640  76–φ48 3865  3730  76–φ60
3600  3620  3970  3860  80–φ56 4005  3890  90–φ60

Technical Parameters of B2F Type (VSSJA-2) Double-Flange Limiting Expansion Joints (PN 1.6, 2.5 MPa)

Nominal Diameter
Nominal
Dia.DN
Pipe outer diameter
Pipe O.D.
Dw
External dimensions
Overall
Dimension
Expansion amount
Linear
Movement
△L
Flange Connection Dimensions
Flange Connection Dimension
1.6MPa 2.5MPa
L L1 D D1 n-do D D1 n-do
65  76  340  105  50  185  145  4-φ18 185  145  8–φ18
80  89  200  160  8–φ18 200  160 
100  108  220  180  235  195  8-φ22
114 
125  133  250  210  270  220  8-φ26
140 
150  159  285  240  8-φ22 300  250 
168 
200  219  340  295  12-φ22 360  310  12-φ26
250  273  405  355  12-φ26 425  370  12-φ30
300  325  350  130  65  460  410  12-φ26 285  430  16–φ30
350  377  520  470  16–φ26 555  490  16-φ32
400  426  580  525  16–φ30 620  550  16–φ36
450  480  640  585  20–φ30 670  600  20–φ36
500  530  715  650  30–φ33 730  660 
600  630  840  770  20–φ36 845  770  20–φ39
700  720  910  840  24-φ36 960  875  24-φ42
800  820  590  220  130  1025  950  24–φ40 1085  990  24-φ48
900  920  1125  1050  28–φ40 1185  1090  28–φ48
1000  1020  1255  1170  28–φ42 1320  1210  28–φ56
1200  1220  1485  1390  32–φ48 1530  1420  32–φ56
1400  1420  1685  1590  36–φ48 1755  1640  36–φ62
1600  1620  1930  1820  40–φ56 1975  1860  40–φ62
1800  1820  2130  2020  44–φ56 2195  2070  44–φ70
2000  2020  2345  2230  48–φ62 2425  2300  48–φ70
2200  2220  2490  2240  50–φ72 2650  3520  50–φ72
2400  2420  2710  2640  50–φ72 2850  2750  50–φ72
2600  2620  600  240  150  2920  2860  52–φ74 3100  2900  52–φ74
2800  2820  3100  3060  52–φ74 3320  3100  52–φ74
3000  3020  3300  3290  54–φ76 3550  3300  54–φ76
3200  3220  3625  3500  54–φ76 3750  3550  54–φ76
3400  3420  3850  3710  60–φ80 3975  3760  60–φ80
3600  3620  4075  3920  60–φ80 4200  3970  60–φ80

Brief Installation Instructions
1. The B2F type (VSSJA-2) double-flange limit expansion joint is suitable for applications where both ends are equipped with valves or flanged connections.
2. All products are fully assembled and tested before leaving the factory. Simply connect both sides of the product to the valve or flange, evenly tighten the nuts adjacent to the gland cover in a diagonal pattern, then adjust the limit nuts as needed.
3. During the pressure test, the pipelines on both sides of the product should be securely fixed to prevent the product from being subjected to excessive axial forces that could damage the piping system.

Related Products